Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V, (21) C13 & (3) C19Introducing the Rack PDU 2G Metered by Outlet ZeroU, a purpose built power distribution solution designed for modern data centers, server rooms, and network closets. This compact, space saving PDU delivers per outlet energy metering and robust protection for critical IT gear, helping you optimize energy usage, improve workload planning, and maintain reliable uptime. With a zeroU footprint, it installs horizontally in a standard 19 inch rack, freeing
Introducing the Rack PDU 2G Metered-by-Outlet ZeroU, a purpose-built power distribution solution designed for modern data centers, server rooms, and network closets. This compact, space-saving PDU delivers per-outlet energy metering and robust protection for critical IT gear, helping you optimize energy usage, improve workload planning, and maintain reliable uptime. With a zeroU footprint, it installs horizontally in a standard 19-inch rack, freeing vertical space for high-density equipment while providing precise, real-time visibility into how power is consumed across every outlet. Built for global deployments, it supports a wide input voltage range and a substantial 16-amp rating, making it a versatile choice for mixed environments where efficient power management is essential. By combining granular metering with a trusted, durable form factor, the Rack PDU 2G empowers IT teams to track, analyze, and optimize consumption at the device level, leading to lower operating costs, better circuit protection, and smarter capacity planning.
- Precision outlet-level metering: Each outlet has its own power measurement, delivering real-time data on voltage, current, and energy usage. This enables precise load balancing, reduces peak demand, and supports detailed capacity planning for data-heavy workloads and dense server configurations.
- Space-saving ZeroU design: The horizontal, 19-inch rack-mountable form factor occupies zero rack units in height, allowing you to maximize available space for racks filled with critical equipment. It’s ideal for dense data centers where every inch of rack space matters.
- Global-ready electrical performance: With a 100-240V input range and a 16A maximum rating, this PDU is suitable for multinational deployments and mixed regions. The broad voltage tolerance helps standardize power infrastructure across campuses, branch offices, and labs without sacrificing reliability.
- Flexible outlet configuration: A total of 24 outlets—21 IEC C13 and 3 IEC C19—provide versatile power distribution for servers, storage devices, network gear, and KVMs. This mix supports a wide range of IT hardware with differing power connector needs.
- Remote monitoring and scalable management: Designed to integrate with data center management tools, networking equipment, and monitoring software. Out-of-band and in-band visibility lets administrators view load, set alarms, and optimize power usage from a central console.
Technical Details of Rack PDU 2G Metered-by-Outlet ZeroU 16A 100-240V (21 C13 & 3 C19)
- Outlet configuration: 21 x IEC C13 outlets and 3 x IEC C19 outlets to support a wide range of IT devices, including servers, switches, storage arrays, and patch panels.
- Current rating: 16A maximum continuous current, suitable for delivering stable power to multiple devices without overloading individual circuits.
- Input voltage range: 100-240V AC, enabling global compatibility and easier standardization of electrical systems across locations.
- Form factor: ZeroU, horizontal 19-inch rack-mountable design that fits in standard racks without consuming vertical space.
- Metering capability: Individual outlet power and energy metering for precise utilization data, enabling granular energy accounting and optimization.
- Protection features: Built-in protection for electrical integrity and overload awareness, helping to safeguard connected equipment and maintain uptime.
- Monitoring interface: Designed for compatibility with network management and monitoring tools via standard interfaces, providing centralized visibility into power usage metrics.
How to Install Rack PDU 2G Metered-by-Outlet ZeroU 16A 100-240V
Installing this PDU is straightforward and designed to minimize downtime while maximizing space efficiency and visibility into power usage. Follow these steps to ensure a safe and reliable setup that delivers the full benefits of outlet-level metering and centralized monitoring.
- Prepare the rack and power source: Confirm that the rack area is clear and that a suitable 100-240V power source is available and accessible. Verify that the supply can handle roughly the expected total load without exceeding 16A.
- Mount the PDU in the rack: Align the PDU with the 19-inch rails of the rack, ensuring it lies flat and sits securely in the intended position. Since this is a ZeroU model, slide it into the rack horizontally and fasten with the appropriate front-m Stripe or mounting hardware according to your rack’s specifications.
- Connect the main power: Plug the PDU’s inlet into the selected power source or power distribution path. Ensure the connection is snug and that all safety precautions are followed to prevent accidental disconnection during maintenance.
- Distribute devices across outlets: Plan device placement to balance load and prevent any single outlet from carrying an excessive share of the total current. Route device cords neatly, using cable management methods to avoid tangling and to facilitate airflow.
- Enable monitoring and validation: Power on the PDU and access the monitoring interface through your preferred management tool or network interface. Verify that outlet-level metering is reporting correctly and that the total load aligns with device expectations. Configure alarms and dashboards to reflect threshold values relevant to your environment.
Frequently asked questions
- Q: What does Metered-by-Outlet mean for power management?
- A: Metered-by-Outlet means each individual outlet has its own meter, providing granular data on energy usage. This enables precise control, load balancing, and data-driven decisions to reduce energy waste and optimize capacity.
- Q: How many outlets are on this PDU and what types are they?
- A: The unit provides 24 outlets in total: 21 IEC C13 outlets and 3 IEC C19 outlets, covering a broad range of IT equipment requirements.
- Q: What is the benefit of the ZeroU form factor?
- A: The ZeroU design allows the PDU to reside in the rack without consuming vertical space, leaving more room for servers and other equipment while still delivering complete power distribution and metering.
- Q: Is this PDU suitable for global deployments?
- A: Yes. With a voltage range of 100-240V, it supports international electrical standards and can be deployed across locations with varying power requirements.
- Q: Can I integrate this PDU with my existing monitoring tools?
- A: The PDU is designed to work with common data center monitoring solutions and management interfaces, enabling centralized visibility of outlet-level energy data and easier capacity planning.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy